WaterShield/Engineering Tools
Filtered for:🌐All Tools
Multi-Vertical Platform Suite

Engineering Tools Hub

Free, browser-based clinical calculators and modeling tools for ASHRAE 188/514 Legionella prevention, ANSI/AAMI ST108:2023 Sterile Processing, and CDC Dental Waterline compliance.

Showing 10 calculators
ASHRAE 188 / CMS QSO-17-30

Audit Exposure Simulator

Calculate your facility's ASHRAE 188, CMS QSO-17-30, and Joint Commission EC.02.05.02 Audit Risk Index (0–100) with citation forecasts and 1-click checklist export.

Potable / Legionella
Launch Calculator
ASHRAE Standard 188

Legionella Risk Matrix

Interactive visualization of pathogen amplification risk based on water temperature, free chlorine residual, and pH.

Potable / LegionellaDental DUWL
Launch Calculator
ASTM B88 / ASHRAE 514

Flush Time & ASTM Dead-Leg Scour

Calculate the exact minutes required to flush a dead leg or pipe run to achieve total volumetric turnover and ASTM B88 scouring velocity (>= 2.0 ft/s).

Potable / LegionellaST-108 SterileDental DUWL
Launch Calculator
EPA / ASHRAE 188 CT Kinetics

Disinfection Concentration × Time (CT)

Verify if your hyperchlorination or chemical sanitization achieves the required Concentration x Time (CT) for specific log-reductions against resilient biofilms.

Potable / LegionellaST-108 SterileDental DUWL
Launch Calculator
Standard Methods 2330

LSI & RSI Water Scaling Index

Langelier Saturation Index (LSI) and Ryznar Stability Index (RSI) tool to determine if water is corrosive or scale-forming across piping and equipment.

Potable / LegionellaST-108 SterileDental DUWL
Launch Calculator
CTI / ASHRAE Standard 188

Cooling Tower Blowdown & CoC

Calculate Cycles of Concentration (CoC), estimated evaporation loss, and required blowdown rates to control mineral scale and Legionella amplification.

Potable / LegionellaST-108 SterileDental DUWL
Launch Calculator
AWWA C651 / ASHRAE 188

Hyperchlorination & Chemical Dosing

Calculate exact physical weight or volume of chemical required to hit target ppm concentration across building plumbing, loops, and reservoirs.

Potable / LegionellaST-108 SterileDental DUWL
Launch Calculator
CDC Model Aquatic Health Code

Hot Tub & Pool Drainage / Turnover

Calculate volume turnover rates and CDC MAHC required bather-load drainage frequency for commercial spas, whirlpools, and therapy pools.

Potable / Legionella
Launch Calculator
AAMI/ANSI/ISO 23500-2

Dialysis Carbon Breakthrough & RO Performance

Verify 4-hour carbon shift breakthrough limits (<0.10 ppm total chlorine) and evaluate RO membrane % rejection and permeate recovery.

ST-108 Sterile
Launch Calculator
ANSI/AAMI ST91:2021

AAMI ST91 Endoscopy Rinse & Purge Drying

Verify Automated Endoscope Reprocessor (AER) final rinse water microbial limits (<10 CFU/100mL) and 10-minute medical air purge channel drying.

ST-108 Sterile
Launch Calculator
Continuous Automated Compliance

Need Enterprise Water Safety Compliance?

Automate sensor telemetry, daily compliance logging, cryptographic audit ledgers, and 1-click surveyor binders across any facility.

Explore WaterShield Ecosystem